We – EPG Group the largest gearbox & motors , couplings and gears manufacturing unit in China with 5 different branches. For much more information: Cell/whatsapp/telegram/Kakao us at: 0086~13083988828 13858117778083988828
2.1 Naming and nameplate identification
2.1.1 Naming rule
JAC300 90KW
Identification | Voltage level |
4 | three-period 380V |
S2 | Solitary-stage 220V |
Identification | Adaptive motor kind |
G | Standard type |
Identification | .four | .seventy five | … | 400 |
Adaptive motor(KW) | .four | .75 | … | 400 |
two.2 Introduction of a variety of parts of the converter
The composition types of JAC580N series converter are the plastic and metal. The exterior diagram is proven beneath.
2.3 Simple technological specification
Desk 2-1 Technical specification of 580N series frequency converter
Item | Specification | ||
Standard capabilities | Highest frequency | Vector management: ~500Hz V/F control: ~500Hz | |
Carrier frequency | 0.8kHz~12kHz The provider frequency is routinely altered primarily based on the load functions. |
||
Input frequency resolution |
Digital environment: .01Hz Analog location: highest frequency x .571% |
||
Manage manner | • Open-loop vector control (SVC) • Closed-loop vector manage (FVC) • Voltage/Frequency (V/F) control |
||
Starting up torque | • G type: .5 Hz/a hundred and fifty% (SVC) Hz/one hundred eighty% (FVC) • P sort: .5 Hz/one hundred% |
||
Basic features |
Pace variety | 1:one hundred (SVC) | one:1000 (FVC) |
Consistent-speed accuracy | ± .5% (SVC) | ± .02% (FVC) | |
Overload capability | • G variety:60s for 150% of the rated existing • P variety: 60s for a hundred and twenty% of the rated recent. |
||
Torque increase | • Fastened increase • Personalized increase .1%-thirty.% |
||
V/F curve | • Straight-line V/F curve • Multi-level V/F curve •N-electrical power V/F curve (1.2-energy, 1.4-electrical power, 1.6-electricity, ,1.8-power, square) |
||
V/F separation | Two types: complete separation fifty percent separation | ||
Acceleration /deceleration curve | • Straight-line ramp • S-curve ramp 4 groups of acceleration/deceleration time with the selection of .-6500.0s |
||
DC bra ept | DC bra ept frequency: .00Hz~highest frequency Bra ept time: .0s~36.0s Bra ept action present value: .%-one hundred.% |
||
JOG management | JOG frequency variety: .00-fifty.00 Hz JOG acceleration/deceleration time: .-6500.0s |
||
Operation | Command resource | Operation panel, control terminal and serial interaction port are offered Swap in numerous approaches |
|
Frequency source | Various frequency sources: electronic reference, analog voltage reference, analog recent reference, pulse reference and serial port reference. The switching can be carried out in a variety of strategies | ||
Auxiliary frequency resource | 10 types of auxiliary frequency source. The auxiliary frequency jog and frequency synthesis can be attained flexibly | ||
Input terminal | Standards: seven digital enter terminals, amid which 1 assist maximum substantial-pace pulse input of 100kHz 2 analog input terminals, amongst which one particular only supports voltage input of ~10V and the other supports voltage enter of ~10V or present input of 4 ~20mA Enlargement ability: three digital input terminals one analog input terminal, which supports voltage enter of -10V ~10V and supports PT100/PT1000 |
||
Output terminal | Standards: one higher-pace pulse output terminal (The open up collector sort is optional), supporting ~100kHz sq. sign output one electronic output terminal 1 relay output terminal 1 analog output terminal, supporting recent output of ~20mA or voltage output of ~10V Enlargement functionality: 1 digital output terminal one relay output terminal 1 analog output terminal, supporting recent output of ~20mA or voltage output of ~10V |
||
Display and keyboard operation | LED show | Display the parameter | |
Crucial lock and operate assortment | Realize partial or all essential lock and outline the motion assortment of some keys to prevent misoperation | ||
Safety purpose | Short circuit test of electrified motor, input/output default period safety, overcurrent protection, overvoltage safety, undervoltage defense, overheat security, overload safety, and so on. |
The use of authentic gear manufacturer’s (OEM) component numbers or logos , e.g. CASE® and John Deere® are for reference purposes only and for indicating merchandise use and compatibility. Our company and the detailed substitution components contained herein are not sponsored, authorized, or made by the OEM.